The Bellman Visit smoke alarm wireless alerting bundle is an
ideal system for anyone who is deaf or has a hearing loss and wants
peace of mind that they will be alerted in the event of a fire or
smoke within their home.
The free-standing, portable receiver alerts you with lights and
sounds and can be placed in close proximity to you so you can have
extra peace of mind that you won't miss a fire or smoke alarm going
off. The flash receiver alerts you with bright strobe lights and
can be easily carried with you around your home. The two smoke
alarm transmitters (optical with heat sensor) can be positioned
around the home to ensure that fire is detected as quickly as
possible.
The Bellman Visit range is ideal for anyone who is deaf or hard
of hearing as it provides alerts via lights, sounds and vibrations,
so you can immediately be notified whenever something happens that
needs your attention in and around your home.
Portable Receiver Features:
- Powerful sound - adjustable up to 93dB
- Clear signal identification - uses LEDs and sound signatures
to alert you
- Long lasting power - up to 3 years battery life
- Bed shaker - place under your pillow for night time
alerts
- Simple to set up - works straight out of the box
Flash Receiver features:
- Bright flash - completely silent alerting
- Alert signal identification via 4 LED coloured lights which
light up the appropriate alert symbol (fire alarm, baby
monitor, doorbell and telephone)
- Rotating top allows you to direct the flashlight
- Multiple connections - outlet for phone and bed shaker
- Battery backup - lasts approx. 48 hours and allows you to
move it around your home with you plus it keeps all features
functional during power loss
Smoke alarm - optical with heat sensor
features:
- Battery supervision - Signals the Visit receiver when the
batteries run low (receivers sold separately)
- Toast mode - Suitable for use in areas with cooking
fumes
- Broadcast mode - relays fire alarms to all Visit units
within range
- Reliable radio link - covers your entire home
- Test button - all smoke alarm systems should be tested
regularly
- Complies with the EN14604: 2005 standard
Inside the box:
BE1450 Portable Receiver, 4 x 1.5V LR14 C size
batteries, wall bracket with screws and plugs & user
manual
BE1442 Flash Receiver, 4 x 1.2v AAA NiMH batteries, Power
Adaptor, User manual
2 x BE1481 Visit smoke alarm, 1 x 9V battery, mounting
bracket, screws and plugs, user manual
BE1270 Bellman Visit Vibrating Bed Shaker
Portable Receiver
Visit indicators:
- Orange LED, pacifier/dummy symbol: The baby monitor is
activated
- Green LED, door symbol: The door transmitter is
activated
- Yellow LED, telephone symbol: The telephone transmitter is
activated
- Red LED, fire symbol: The smoke alarm is activated
Features:
- Clear signal identification: Coloured LEDs and individual
sound signatures
- Adjustable sound signal: Max 93dBA @ 1m, frequency range:
500-1000Hz
- Long lasting power: up to 3 years battery life
- Bed shaker outlet: 2.0-4.0 VDC (BE1450)
- Speaker outlet: 10k ohm, 0-4V (BE1452)
Frequency and coverage:
- Radio frequency: 868.3 MHz
- Coverage: 50 – 250metres depending on the radio frequency and
building’s characteristics
Power and battery:
- Supply 7.5 V DC / 1500 mA
- Battery Power 4 x 1.5V LR14 alkaline batteries
- Power consumption: Active: 1000 mA, idle position: 0.1
mA
- Operating time: 2-3 years with alkaline batteries
Flash Receiver
Visit indicators:
- Orange LED, pacifier/dummy symbol: The baby monitor is
activated
- Green LED, door symbol: The door transmitter is
activated
- Yellow LED, telephone symbol: The telephone transmitter is
activated
- Red LED, fire symbol: The smoke alarm is activated
Features:
- Alerting signal: Built-in flash light ~30 Candela Xenon light
*Warning! Flashes can cause epileptic
attacks.
- Activation:
- Via the Visit transmitters
- Via the analogue telephone network
- Via mobile phones/tablets (BE9250 required)
Frequency and coverage:
- Radio frequency: 315 MHz, 433.92 MHz or 868.3 MHz, depending
on the region
- Coverage: 50 – 250 m, depending on the radio frequency and
building’s characteristics
Power and battery:
- Mains power 7.5 V DC / 1500 mA with power supply unit
- Power consumption: Active: 1250 mA, idle position: 10 mA
- Operation time: ~48 h when fully charged
Smoke alarm - optical with heat sensor
Features:
- Sensor type - optothermal sensor
- BE1481 complies with the following smoke alarm standard:
EN14604: 2005
- Audible alarm > 85dB (A) at 3m
- Activation:
- Via test and silence button
- Via the smoke detector
- Via the temperature sensor, if the temperature
exceeds approx 57 degrees celcius
- Antenna direction - the antenna should be straight and
pointed directly down to achieve the best coverage between
smoke alarms and Visit receivers
Frequency and coverage:
- Radio frequency: 868.3 MHz
- Coverage: up to 200m clean line of sight, depending on
the radio frequency and building’s characteristics
Power and battery:
- Supply - 9V battery
- Power consumption: Active: 40 mA, idle position: <10
mA
- Operating time: 3 years with alkaline battery, 6 years